Dental X-ray Machine
Showing all 7 results
-
Dental Cone Beam Computed Tomography System AM-ADM-3000A
- Clinical Application
Oral and maxillofacial cone beam computed tomography equipment
(dental CT) with 12cmX15cm flat panel detector, can be widely used in
oral and maxillofacial surgery, orthodontics, orthognathic surgery,
implant, dental, temporomandibular joint Preoperative and postoperative.
-
Dental X-ray Unit ADM-10B
- Specifications
Classification: Electrometrical, Class I, Type B
Power supply: 220V±10%, 50Hz, 1kVA
Tube voltage: 60KVp
Tube current: 8mA
Focus size: 1.5mm
Total filtration: 2.5mmAL
Exposure time: 0.2 to 4 sec
Leak radiation: Outside one meter≤0.002mGy/h
(National standard: 0.25mGy/h)
Optional: Tube current: 0.5mA
Focus size: 0.8mm
-
Dental X-ray Unit AM-ADM-10D
- Specifications
Classification: Electrometrical, Class I, Type B
Power supply: 220V±10%, 50Hz, 1kVA
Tube voltage: 60KVp
Tube current: 8mA
Focus size: 1.5mm
Total filtration: 2.5mmAL
Exposure time: 0.2 to 4 sec
Leak radiation: Outside one meter≤0.002mGy/h
(National standard: 0.25mGy/h)
Optional: Tube current: 0.5mA
Focus size: 0.8mm
-
Digital Dental X-ray Sensor AM-DS530
Description:
Material: APS
Sensing area:30X20mm (600mm2)
Sensor Pixels:3.2 million pixels
Pixel size:19x19um
Resolution:> 20 lp / mm
Gray scale:12 bit
Life:> 100000 times
Dimensions:37.0×24.5×5.5mm
Line length (Material – Polyurethane):3m
Connection:USB standard
-
Handheld High Frequency Dental X-ray Unit AM-ADM-10P
- Specifications
Frequency: 32KHZ
Tube voltage: 60KV
Tube current: 1.5mA
Exposure time: 0.02-4sec
Distance from skin to cone: 130mm
Tube focus: 0.3mm*0.3mm
Output voltage: DC16.8V
Battery: DC14.8V, 6400mAh
Leak radiation: Outside one meter≤0.002mGy/h
(National standard: 0.25mGy/h)
Ambient temperature: 5℃~40℃
Relative temperature: <75%RH
Optional color: grey, pink, light green
-
High Frequency Dental X-ray Unit AM-ADM-10A
- Specifications
Power supply: AC220V±10%
or AC110V±10%, 50/60HZ
Frequency: 200KHZ
Tube voltage: 70KV
Tube current: 8mA
Focus size: 0.8mm
Total filtration: 2.5mmAL
Exposure time: 0.02-4sec
Leak radiation: Outside one meter≤0.002mGy/h
(National standard: 0.25mGy/h)
-
Mobile High Frequency Dental X-ray Unit AM-ADM-10P
- Specifications
Frequency: 32KHZ
Tube voltage: 60KV
Tube current: 1.5mA
Exposure time: 0.02-4sec
Distance from skin to cone: 130mm
Tube focus: 0.3mm*0.3mm
Output voltage: DC16.8V
Battery: DC14.8V, 6400mAh
Leak radiation: Outside one meter≤0.002mGy/h
(National standard: 0.25mGy/h)
Ambient temperature: 5℃~40℃
Relative temperature: <75%RH
Optional color: grey, pink, light green
ADM-10P Mobile X-ray Machine is with remote control exposure function