Horizontal Cylindrical Pressure Steam Sterilizer AM-WS-400/500YDA
Saturated pressure steam is used to sterilize article, for it will liberate a great amount of heat when condensing. To make the articles (need to be sterilized) hot and wet for a certain time, most resistant bacterial spores will be killed, and then sterilization aim is reached. The method is reliable, economical, and easy to be controlled, so it has been used for more than one hundred years.
This unit is ideal equipment for clinics, scientific research institutes and other organizations to sterilize surgical instruments, fabric glassed, culture media etc.
-
Horizontal Cylindrical Pressure Steam Sterilizer AM-WS-YDA
Characteristics
- The steam can’t go through to chamber when the door hasn’t been closed, and the pilot off inform. You can process dry operate.
- When the pressure inner over 0.027MPa, the door be locked and can’t be open.
- If you not choose the sterile time and start the machine, buzzer sound.
- If you mistake open the door in the course of start, the jacket value auto off and open the chamber value.
- Lack water the pilot on, heating and sterile pilot off, the buzzer sound and auto release steam.
- Overload and leakage protection, when leakage or over current occur, it auto off the power.
- Temperature controlled not work and the inner pressure over 0.165MPa, the safety value auto start opens.
-
Horizontal Cylindrical Pressure Steam Sterilizer AM-WS-YDB
Characteristics
- Sterilizing course automatic sterilization controlled by computer, easy to operate.
- With drying function, suitable dressing drying.
- With over-temperature, over-pressure auto-protect device.
- The door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027MPa.It can’t be start on if the doesn’t closed well.
- The safety value will be open automatically when the inner pressure over 0.24MPa, and the steam be exhausting to the water tank.
- The power will be cut-off automatically, cut-off the water and alarm when the machine lacking water.
-
Horizontal Cylindrical Pressure Steam Sterilizer AM-WS-YDC
Characteristics
- The steam can’t go through to chamber when the door is not close, and the pilot off inform. You can process dry operate.
- When the pressure inner over 0.027MPa, the door be locked and can’t be open.
- If you not choose the sterile time and start the machine, buzzer sound.
- If you mistake open the door in the course of start, the jacket value auto off and open the chamber value.
- Lack water the pilot on, heating and sterile pilot off, the buzzer sound and auto release steam.
- Overload and leakage protection, when leakage or over current occur, it auto off the power.
- Temperature controlled not work and the inner pressure over 0.165MPa, the safety value auto start opens.