fbpx

Modular Patient Monitor AM-800D

AM-800D

Modular Patient Monitor AM-800D

Intoduction

The multi-parameter monitor is composed of host, battery, display screen, parameter module, parameter module plug-in box and accessories (pulse saturation probe, body temperature probe, ECG lead, blood pressure cuff, sampling tube). This monitor supports hot plugging for Plug-In Module, where they can be plugged without turning off the monitor.

Standard Para: lead ECG, RESP, SpO2, 2-TEMP, NIBP, PR/HR

Optional Para: 2-IBP, EtCO2, touch screen, recorder, 12-lead ECG, cardiac output, anesthesia depth EEG, CMS

Features

-Suitable for adults, children, and newborns.

-12.1/15.6 inches color LCD screen with optional touch screen and rotator knob.

-Upgradable module is interchangeable (plug and play type).

-Capable to visualize 6 or more waveform.

-Support color coding for different waveform.

-28 ST segment analysis with ST trend with continuous display of ST value on screen.

-Multiple screen layout to view big font size in numeric and waveform.

-Trending facilities for up to 360 hours of both graphical & numerical along with event review facility for all parameters and full waveform disclosure facility.

-Different visual alarm with color coding and audible alarms for various parameters with three levels of volume adjustment.

-Support HL7 protocol to access the central workstation

-Energy-saving, low-power design, extending battery life

-Configure noise reduction fan to ensure a quieter and cleaner environment Arrhythmia detection and analysis in various leads.

-5200mAh built-in battery backup of 4 hours

-Dimension: 30cm*15cm*30cm for ARI-800D, 38*15*30cm for ARI-800D+

Technical Specifications

PARAMETER

SPECIFICATION

Display
Size: ARI-800D: 12.1 inches Color TFT LCD ARI-800D+: 15.6 inches Color TFT LCD Resolution: ARI-800D: 1024*768 pixels ARI-800D+: 1366*768 pixels
ECG
ECG Range: 0.15~5.5mV ECG Resolution: 2.36uV/LSB HR Range: 15~300bpm (adult) 15~350bpm (child/neonate) HR Accuracy: ±1bpm or ±1% (whichever is greater) RR Range: 0~120bpm RR Accuracy: 15~120rpm: ±2rpm or ±2% <15rpm: Undefined Sweep speed: 6.25 mm/s, 12.5mm/s, 25mm/s, 50mm/s, less than ±5% error Display sensitivity: 2.5 mm/mV (X0.25), 5 mm/mV (X0.5), 10 mm/mV (X1), 20 mm/mV (X2), 40 mm/mV (X4), Auto, less than ±5% error
spO2
SPO2 Range: 0~100% SPO2 Accuracy: 70~100%, ±2% <70%, Undefined PI Range: 0~20% PVI Range: 0.001% PR Range: 25-250bpm PR Accuracy: ±2bpm or ±2% (whichever is greater)
TEMP
Technique: Thermal resistance Measurement Range: 0~50.0℃ Accuracy: ±0.2°C Resolution: 0.1°C Refresh Rate: 1s Alarm limit range: Temp High: (low limit +0.1℃) ~ 50.0℃ Temp Low: 0℃ ~ (high limit -0.1℃)
NIBP
Technique: Oscillometry Mode of operation: Manual, Auto, STAT, Sequence Pressure Range: 0~300mmHg Pressure Accuracy: ±2mmHg or ±1% of reading (whichever is greater) Resolution: 1mmHg SYS Range: Adult: 40-270mmHg Pediatric: 40-200mmHg Neonate: 40-135mmHg DIA Range: Adult: 10-210mmHg Pediatric: 10-150mmHg Neonate: 10-100mmHg Mean Range: Adult: 20-230mmHg Pediatric: 20-165mmHg Neonate: 20-110mmHg Accuracy: the mean deviation<±5mmHg, the standard deviation<8mmHg
Respiration
Technique: Trans-thoracic impedance Lead: Options are lead I and II Respiration excitation waveform: <300µA RMS, 62.8kHz (±0%) Respiration impedance range: 0.3~5Ω Baseline impedance range: 200~2500Ω (using an ECG cable with 1kΩ resistance) Bandwidth: 0.2~2Hz (-3 dB) Sweep speed: 6.25 mm/s, 12.5mm/s, 25mm/s, 50mm/s
PR
Measurement range: 25bpm~250bpm Resolution: 1bpm Accuracy: ±3bpm Alarm limit: PR High: (PR Low limit +1bpm) ~ 300bpm PR Low: 15bpm ~ (PR High limit -1bpm)
HR
Measurement range: 15~300bpm (adult) 15~350bpm (pediatric/neonate) Resolution: 1bpm Accuracy: ±1 bpm or ±1%, whichever is greater Sensitivity: 0.2mV
Data Storage
Trends: 60 hours trend data with the resolution no less than 1 minute. 4 hours trend data with the resolution no less than 5 second. Events: 100 events NIBP measurements: 40 events Interpretation of resting 12-lead ECG results: 25 sets
IBP(optional)
Pressure Range: -50~350mmHg (-6.7kPa~40.0kPa) Accuracy: ±2% or ±1 mmHg, whichever is greater (excluding sensor error) Resolution: 1 mmHg (0.1kPa) Sensitivity: 5μV/V/mmHg Zero adjustment range: ±200 mmHg Impedance range: 300~3000Ω Volume displacement: <0.04mm³/100mmHg
CO(optional)
Range: 0.20~20.00L/Min Accuracy: ±5%
ETCO2 (Optional)
CO2 Range: 0~20.0vol% CO2 Accuracy: 0~12 vol%: ± (0.2 vol%+2% of reading) 12~20 vol%: ± (0.2 vol%+6% of reading) AwRR Range: 0~150rpm Resolution: 1 rpm AwRR Accuracy: Mainstream: 0~150rpm, ±1rpm Sidestream: 0~69rpm, ±1rpm; 70~150rpm, Undefined