Deprecated: Return type of Ai1wm_Recursive_Directory_Iterator::hasChildren($allow_links = true) should either be compatible with RecursiveDirectoryIterator::hasChildren(bool $allowLinks = false): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/iterator/class-ai1wm-recursive-directory-iterator.php on line 57

Deprecated: Return type of Ai1wm_Recursive_Directory_Iterator::rewind() should either be compatible with FilesystemIterator::rewind(): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/iterator/class-ai1wm-recursive-directory-iterator.php on line 35

Deprecated: Return type of Ai1wm_Recursive_Directory_Iterator::next() should either be compatible with DirectoryIterator::next(): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/iterator/class-ai1wm-recursive-directory-iterator.php on line 42

Deprecated: Return type of Ai1wm_Recursive_Extension_Filter::getChildren() should either be compatible with RecursiveFilterIterator::getChildren(): ?RecursiveFilterIterator, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-extension-filter.php on line 47

Deprecated: Return type of Ai1wm_Recursive_Extension_Filter::accept() should either be compatible with FilterIterator::accept(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-extension-filter.php on line 37

Deprecated: Return type of Ai1wm_Recursive_Exclude_Filter::getChildren() should either be compatible with RecursiveFilterIterator::getChildren(): ?RecursiveFilterIterator, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-exclude-filter.php on line 41

Deprecated: Return type of Ai1wm_Recursive_Exclude_Filter::accept() should either be compatible with FilterIterator::accept(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-exclude-filter.php on line 37

Deprecated: Return type of Ai1wm_Recursive_Newline_Filter::accept() should either be compatible with FilterIterator::accept(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-newline-filter.php on line 28

Deprecated: Optional parameter $path declared before required parameter $modulename is implicitly treated as a required parameter in /home/apicalmedmain/public_html/wp-content/plugins/zoho-crm-forms/includes/crmapiintergration.php on line 102
Mobile X-ray Radiography Equipment AM-NKX-50 - Apicalmed Ltd
Search
Close this search box.
X
  • No products in the list

Mobile X-ray Radiography Equipment AM-NKX-50

AM-NKX-50

Mobile X-ray Radiography Equipment AM-NKX-50

Features

  1. For photography in hospital wards and emergency rooms.
  2. Flexible mobile operation performance.
  3. Wireless remote exposure, greatly reducing the radiation dose of physicia

Technical Specifications

PARAMETER

SPECIFICATION

Power Supply
Single phase AC three-wire system, voltage 180V~250V; Frequency 50Hz; source resistance ≤ 0.22Ω; Capacity 8kW; max current 37A (instant)
Radiography
Power supply voltage: AC 220V ± 22V; Power frequency: 50Hz ± 0.5Hz; Power capacity: ≥5kVA; Maximum allowable internal resistance of power supply: 1Ω
X-ray tube focus
Tube voltage: 40-90kV 11 levels, 5kV each; Tube current: 2 levels of 30 and 50mA; Time: 0.05s-6s in 20 levels.
Mechanical properties
When the X-ray generator window is down, the range of focus from the ground is 450mm ~ 1770mm; The rotation angle of X-ray generator around the horizontal axis is ±180°; The rotation angle of X-ray generator around the vertical axis is ± 90º;
Overall dimensions
1290(L)×680(W)×1935(H)(mm)