Deprecated: Return type of Ai1wm_Recursive_Directory_Iterator::hasChildren($allow_links = true) should either be compatible with RecursiveDirectoryIterator::hasChildren(bool $allowLinks = false): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/iterator/class-ai1wm-recursive-directory-iterator.php on line 57

Deprecated: Return type of Ai1wm_Recursive_Directory_Iterator::rewind() should either be compatible with FilesystemIterator::rewind(): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/iterator/class-ai1wm-recursive-directory-iterator.php on line 35

Deprecated: Return type of Ai1wm_Recursive_Directory_Iterator::next() should either be compatible with DirectoryIterator::next(): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/iterator/class-ai1wm-recursive-directory-iterator.php on line 42

Deprecated: Return type of Ai1wm_Recursive_Extension_Filter::getChildren() should either be compatible with RecursiveFilterIterator::getChildren(): ?RecursiveFilterIterator, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-extension-filter.php on line 47

Deprecated: Return type of Ai1wm_Recursive_Extension_Filter::accept() should either be compatible with FilterIterator::accept(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-extension-filter.php on line 37

Deprecated: Return type of Ai1wm_Recursive_Exclude_Filter::getChildren() should either be compatible with RecursiveFilterIterator::getChildren(): ?RecursiveFilterIterator, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-exclude-filter.php on line 41

Deprecated: Return type of Ai1wm_Recursive_Exclude_Filter::accept() should either be compatible with FilterIterator::accept(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-exclude-filter.php on line 37

Deprecated: Return type of Ai1wm_Recursive_Newline_Filter::accept() should either be compatible with FilterIterator::accept(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-newline-filter.php on line 28

Deprecated: Optional parameter $path declared before required parameter $modulename is implicitly treated as a required parameter in /home/apicalmedmain/public_html/wp-content/plugins/zoho-crm-forms/includes/crmapiintergration.php on line 102
Medical Freezer (-10 ~ -25°C/-30 ~ -40°C) AM-ADF-25V278W -
Search
Close this search box.
X
  • No products in the list

Medical Freezer (-10 ~ -25°C/-30 ~ -40°C) AM-ADF-25V278W

AM-ADF-25V278W

Medical Freezer (-10 ~ -25°C/-30 ~ -40°C) AM-ADF-25V278W

Features

-Accurate microprocessor controller to ensure consistent cabinet temperature -10~-25°C and increment 0.1°C.

-Adjustable height of plastic-coated fabric grid, more uniform temperature.

-Wide available voltage range: 187V~242V.

-High ambient temperature controller setting password to prevent unauthorized access.

-7 drawers to prevent cold air from leaking out when the out-door is opening.

-Power failure protection: turn on delay of the cooling system when power failure.

-Controller error protection: the cooling system will remember the normal working cycle and keep working depending on this memory when controller or two sensors failed.

Technical Specifications

Performance
Cooling method Direct cooling
Defrost Manual
Shelf/drawer 7
Temperature range -10~-25
Ambient temperature 10~32℃
Noise (db) 46

 

Refrigeration System
Refrigerant R290
Temp.controller Microprocessor
Sensor NTC
Display Digital
Internal material SPCC sprayed steel
External material SPCC sprayed steel
Compressor DONPERN/1

 

Alarms
High/low temperature Y
Power off /
Sensor malfunction Y
Ambient temperature (℃) /
Abnormal voltage /
Temperature controller malfunction Y
Door ajar Y
Power failure backup system (alarm) /

 

Electrical Data
Voltage Frequency (v/Hz) 220V 50Hz
Power(W) 195W
Current (A) 1.58A
Power consumption 2.45kWh/24h

 

Dimensions
Capacity (L/cu.ft) 278/9.81
Exterior size (W*D*H)(mm) 659*600*1694
Interior size (W*D*H)(mm) 480*415*1460
Package size (W*D*H)(mm) 710*678*1770
CBM 0.90
NT./GT.(kg) 105/115

 

Other
Castor Y
Access port QTY/Dia. 1/25mm
USB port /
Data logger Optional
Remote alarm port /