Deprecated: Return type of Ai1wm_Recursive_Directory_Iterator::hasChildren($allow_links = true) should either be compatible with RecursiveDirectoryIterator::hasChildren(bool $allowLinks = false): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/iterator/class-ai1wm-recursive-directory-iterator.php on line 57

Deprecated: Return type of Ai1wm_Recursive_Directory_Iterator::rewind() should either be compatible with FilesystemIterator::rewind(): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/iterator/class-ai1wm-recursive-directory-iterator.php on line 35

Deprecated: Return type of Ai1wm_Recursive_Directory_Iterator::next() should either be compatible with DirectoryIterator::next(): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/iterator/class-ai1wm-recursive-directory-iterator.php on line 42

Deprecated: Return type of Ai1wm_Recursive_Extension_Filter::getChildren() should either be compatible with RecursiveFilterIterator::getChildren(): ?RecursiveFilterIterator, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-extension-filter.php on line 47

Deprecated: Return type of Ai1wm_Recursive_Extension_Filter::accept() should either be compatible with FilterIterator::accept(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-extension-filter.php on line 37

Deprecated: Return type of Ai1wm_Recursive_Exclude_Filter::getChildren() should either be compatible with RecursiveFilterIterator::getChildren(): ?RecursiveFilterIterator, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-exclude-filter.php on line 41

Deprecated: Return type of Ai1wm_Recursive_Exclude_Filter::accept() should either be compatible with FilterIterator::accept(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-exclude-filter.php on line 37

Deprecated: Return type of Ai1wm_Recursive_Newline_Filter::accept() should either be compatible with FilterIterator::accept(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-newline-filter.php on line 28

Deprecated: Optional parameter $path declared before required parameter $modulename is implicitly treated as a required parameter in /home/apicalmedmain/public_html/wp-content/plugins/zoho-crm-forms/includes/crmapiintergration.php on line 102
Defibrillator AM-DEF-8000C - Apicalmed Ltd
Search
Close this search box.
X
  • No products in the list

Defibrillator AM-DEF-8000C

AM-DEF-8000C

Defibrillator AM-DEF-8000C

Defibrillation

-Defibrillation type              Manual, Synchronized, Asynchronized

-Output waveform              Biphasic technology

-Energy accuracy               <+1%

-Energy selection            0,3,5,7,10,20,30,50,100,200,300,360 Joule (Nominal at a resistance of 50)

-Charging time                   Maximum 10 seconds to 360 Joule

-Paddles                Reusable external adult paddles (Pediatric paddles integrated)

Power requirements

-AC Power supply              110V, 60 Hz /220V, 50 Hz

-Vehicle Voltage          DC 12V Li-ion battery

Internal Battery

-Battery type                Rechargeable lithium battery

-Charging time                Time-Minimum of 4 hours for full charging

-Battery charging         During AC Power Supply operation of the device

-Charging /Low Battery Indication      Red LED

-Battery Capacity        100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 joules

 

Display

-LED Dimensions         7’diagonal {155mm*88mm}

-Type                           High resolution true-color graphic LED

-Resolution                 480X234

ECG

ECG lead: I, II, III, AVR, AVL, AVF, V1-V6, GND

S-T segment analysis: -2.0-2.0mv

Arrhythmia analysis: yes

Protection: Withstand 4000vAc/50Hz voltage in isolation and work against electrosurgical interfere and defibrillation

 

NIBP

Working mode: Manual/Automatic/stat (5 minutes)

Method: Automatic oscillation

Cuff type: standard Adult; optional Pediatric/Neonatal

Temperature

Measurement range 20~45°C

Resolution 0.1°C

SpO2

Display: spo2 value, pulse histogram, waveform, pulse

Range: 0~99%for adult, pediatric and neonatal patients

Probe: standard adult finger clip

Optional pediatric Y-type clip and neonatal wrap

Pulse

Pulse range: 0-300bpm

Pulse accuracy: ±2bpm

Built-in Recorder

-Paper: 50mm thermal.

-Printing Method: High-resolution, thermal print head.

-Record date, time sweep speed, waveform gain, heart rate, energy (joule) and ECG waveform

-Print mode

HR exceed limits alarm recording

Auto timed recording

Real-Time Recording

Defibrillation discharge trigger recording

Configuration

Standard Parameter

Biphasic Defibrillation, ECG, NIBP, TEMP, SPO2, Pulse, Recorder

 

Optional AED

Adult Mode: 150J/150J/200J, 120J/120J/150J

Children Mode: 50J/50J/75J, 30J/30J/50J

 

Optional Pacer

Technical Specifications

PARAMETER

SPECIFICATION

Scroll to Top