Deprecated: Return type of Ai1wm_Recursive_Directory_Iterator::hasChildren($allow_links = true) should either be compatible with RecursiveDirectoryIterator::hasChildren(bool $allowLinks = false): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/iterator/class-ai1wm-recursive-directory-iterator.php on line 57

Deprecated: Return type of Ai1wm_Recursive_Directory_Iterator::rewind() should either be compatible with FilesystemIterator::rewind(): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/iterator/class-ai1wm-recursive-directory-iterator.php on line 35

Deprecated: Return type of Ai1wm_Recursive_Directory_Iterator::next() should either be compatible with DirectoryIterator::next(): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/iterator/class-ai1wm-recursive-directory-iterator.php on line 42

Deprecated: Return type of Ai1wm_Recursive_Extension_Filter::getChildren() should either be compatible with RecursiveFilterIterator::getChildren(): ?RecursiveFilterIterator, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-extension-filter.php on line 47

Deprecated: Return type of Ai1wm_Recursive_Extension_Filter::accept() should either be compatible with FilterIterator::accept(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-extension-filter.php on line 37

Deprecated: Return type of Ai1wm_Recursive_Exclude_Filter::getChildren() should either be compatible with RecursiveFilterIterator::getChildren(): ?RecursiveFilterIterator, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-exclude-filter.php on line 41

Deprecated: Return type of Ai1wm_Recursive_Exclude_Filter::accept() should either be compatible with FilterIterator::accept(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-exclude-filter.php on line 37

Deprecated: Return type of Ai1wm_Recursive_Newline_Filter::accept() should either be compatible with FilterIterator::accept(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-newline-filter.php on line 28

Deprecated: Optional parameter $path declared before required parameter $modulename is implicitly treated as a required parameter in /home/apicalmedmain/public_html/wp-content/plugins/zoho-crm-forms/includes/crmapiintergration.php on line 102
Chemistry Analyzer AM-3002B1 - Apicalmed Ltd
Search
Close this search box.
X
  • No products in the list

Chemistry Analyzer AM-3002B1

AM-3002B1

Chemistry Analyzer AM-3002B1

Features

1. 10 incubators and three timers
2. 7 inch Color LCD , Touch screen
3. Flow cell and Cuvette test mode compatible
4. Real time curve showing
5. 7 wavelength , 90 test item pre-programmed
6. Memory for 10,000 sample results
7. Light source hibernate function making lamp life longer
8. RS232 interface, PC connecting

Technical Specifications

PARAMETER SPECIFICATION
Test mode Kinetic, End point, Two point, Absorbance
Wavelength 7 standard filters, 340, 405, 492, 510, 546, 578, 630 nm, 1 free position
Wavelength precision ±2 nm, width ≤ 10nm
Absorbance range 0~4.500 Abs
Absorbance precision outside 0.0001 Abs , inside 0.00001 Abs
carry over < 1%
Repeatability CV < 1%
Incubator 37°C、30°C、25°C、Precision : ±0.1°C
Sample volume 0~3000 uL (≥500uL recommend)
Data Storage ≥10000
Quality control curve X-bar,SD、CV%、L-J quality control curve for every test item
Flow cell 32 uL quartz glass, 10 mm
Lamp Philips 6V 10W Halogen Lamp with long life
Screen 7 inch color LCD
CPU ARM series high speed micro CPU
Printer Internal thermal sensitive printer
Interface RS-232
Work Environment Temperature 0°C ~ 40°C, Humidity: ≤80%
Power supply 100~240VAC,50-60Hz,100VA
Dimension 340(L)*270(W)*160(H)
Weight 5 kg
Usual test list

Liver function ALT  AST  ALP  T-BIL  D-BIL  TP  ALB  TTT  CHE  Nh3
Renal function BUN  CRE  UA  URE  CO2-CP  γ-GT
Lipids T-CHO  TG  HDL-C  LDL-C
Cardiac function CK  CK-MB  LDH
Immune proteins IGA  IGG  IGM  C3
Others GLU  HGB  AMS

Technical Specifications

PARAMETER

SPECIFICATION