Deprecated: Return type of Ai1wm_Recursive_Directory_Iterator::hasChildren($allow_links = true) should either be compatible with RecursiveDirectoryIterator::hasChildren(bool $allowLinks = false): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/iterator/class-ai1wm-recursive-directory-iterator.php on line 57

Deprecated: Return type of Ai1wm_Recursive_Directory_Iterator::rewind() should either be compatible with FilesystemIterator::rewind(): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/iterator/class-ai1wm-recursive-directory-iterator.php on line 35

Deprecated: Return type of Ai1wm_Recursive_Directory_Iterator::next() should either be compatible with DirectoryIterator::next(): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/iterator/class-ai1wm-recursive-directory-iterator.php on line 42

Deprecated: Return type of Ai1wm_Recursive_Extension_Filter::getChildren() should either be compatible with RecursiveFilterIterator::getChildren(): ?RecursiveFilterIterator, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-extension-filter.php on line 47

Deprecated: Return type of Ai1wm_Recursive_Extension_Filter::accept() should either be compatible with FilterIterator::accept(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-extension-filter.php on line 37

Deprecated: Return type of Ai1wm_Recursive_Exclude_Filter::getChildren() should either be compatible with RecursiveFilterIterator::getChildren(): ?RecursiveFilterIterator, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-exclude-filter.php on line 41

Deprecated: Return type of Ai1wm_Recursive_Exclude_Filter::accept() should either be compatible with FilterIterator::accept(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-exclude-filter.php on line 37

Deprecated: Return type of Ai1wm_Recursive_Newline_Filter::accept() should either be compatible with FilterIterator::accept(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/apicalmedmain/public_html/wp-content/plugins/all-in-one-wp-migration/lib/vendor/servmask/filter/class-ai1wm-recursive-newline-filter.php on line 28

Deprecated: Optional parameter $path declared before required parameter $modulename is implicitly treated as a required parameter in /home/apicalmedmain/public_html/wp-content/plugins/zoho-crm-forms/includes/crmapiintergration.php on line 102
Portable Ventilator AM-100C - Apicalmed Ltd
Search
Close this search box.
X
  • No products in the list

Portable Ventilator AM-100C

AM-100C

Portable Ventilator AM-100C

Technical specifications

Physical characteristics

Dimensions: width 300 mm, depth 160 mm, height 230 mm, weight 3 kg

Dimensions of transport packages: width 460 mm, depth 200 mm, height 400 mm, weight 7 kg

Packaging dimensions: width 620 mm, depth 240 mm, height 410 mm, weight 11 kg

Storage/Shipping Requirements

Temperature: -20 to 70°C

Relative humidity less than 93%

Atmospheric pressure: 70 to 106 kPa

 

Operating requirements

Temperature: 5 to 40°C

Relative humidity less than 80%

Atmospheric pressure: 70 to 106 kPa

 

Electrical characteristics

Input Voltage Requirements: AC Voltage 110V~240V; DC Voltage 12V

Input battery: 12V, 2Ah (can be used for 8 hours)

Frequency: 50Hz / 60Hz

Power: 2A

 

Pneumatic specifications

Pressurized oxygen: 0.4 MPa medical oxygen inlet or use of a 2 L oxygen cylinder (suppliers' choice)

 

Performance characteristics

On/Off

Modes: CMV(IPPV), A/C(SIPPV), SIMV, SPONT, PEEP (Supplier Choice)

Tidal volume: 50~1200ml

Respiratory rate: 5~60 bpm

PEEP: 0 ~ 2 kPa

O2%: 45~90%

Sigh: 1~10 per 100 breaths

Peep: 10-60hpa (Supplier's choice)

Trigger level: -10 ~ 0hpa

Above pressure relief: <6kpa

 

Alarms and indicators

High pressure alarm limit: 2~6 kpa flash, red indicator

Low pressure alarm limit: 0.2~2 kpa red indicator

Alarm silence: 120sec

standard accessories

Fan 1 unit

1pcs Oxygen Cylinder (2.5L can be used for 1 hour)

1-piece breathing circuit (1.2 m)

1 piece transport packaging (all parts inside)

Breath value 1pcs

1pcs mask

1 piece charger

1pcs battery (can be used for 8 hours)

1pcs key

1pcs Oxygen Pressure Reducer (for normal oxygen cylinder)

1 piece lung simulators

1 piece hand book

CD for operation 1 piece

Scope of the medical respirator

For first aid

For ambulance

For transport

Technical Specifications

PARAMETER

SPECIFICATION